- Actalyke® MINI II -
Activated Clotting Time (ACT) Analyzer

Cat. No. Item
 5753   Actalyke MINI II Analyzer, 110/220V (w/printer)
 5755   Actalyke MINI II Analyzer, 110/220V (without printer)
 5763   Actalyke MINI II, 110/220V (with printer and battery)
 5765   Actalyke MINI II, 110/220V (with battery)
 1197   Comprehensive Replacement for Actalyke MINI II Analyzer
 9134   Service Manual for Actalyke MINI II
 
The MINI II is the simplest, least expensive ACT instrument available, yet it retains high sensitivity, 2-point clot detection for greatest reliability. Performance, linearity and CVs parallel larger Actalyke analyzers. It?s ideal for use in the catheterization, dialysis or the surgical suite. Optional battery pack available.

6" Footprint - The MINI II features a very small footprint, but has a very large high visibility screen. Operation of the MINI II is extremely simple. Just insert the ACT reagent tube containing whole blood and push the button.

Full Cross-Compatibility - The MINI II is fully compatible with all ACT tubes. Helena offers a full line of Actalyke ACT tubes, including traditional glass bead, kaolin and celite, plus new MAX-ACT.

Actalyke MINI II Specifications
Tests: Whole Blood Activated Clotting Time (ACT). Accepts Actalyke ACT Tubes with celite, kaolin, glass-bead activators; MAX-ACT Tubes with blended activators; all International Technidyne Hemochron® tubes

  Measurement Range   0-1500 seconds
  Incubation Temperature   36.5℃ - 37.5℃  (97.7℉ - 99.5℉)
  Dimensions   6.1"W x 4.8"H x 6.3"L (15.5 x 12.2 x 16.0 cm)
  Display   3.2 x 1" (8 x 2.54 cm)
  Weight (with printer)   5.3 lbs. (2.4 kg) (with battery):
  Line Voltage   47-63 Hz, 85-265 V A/C (Battery optional - DC)
  Environment   15℃ to 30℃ (59 to 86℉)
  Data transfer capability   Printer option available for hard copy
  CLIA Classification   Non-waived
 
 
 
- Actalyke MINI II and MINI Accessories and Supplies -
 
Cat. No. Item
 5754   Actalyke MINI II Battery Pack
 5757   Actalyke Thermometer
 A-PPR   Actalyke Thermal Printer Paper (3 rolls)
 XL-ECT   Actalyke Electronic Clotting Tube
 9132   Service Manual Actalyke MINI
 
 
 
- Actalyke Reagent Tubes for Activated Clotting Time -
 
MAX-ACT™ Tubes

Cat. No. Item
MAX-ACT MAX-ACT Tubes (Gray Flip-Top), 50 tubes/box

MAX-ACT Tubes, with an upper linearity limit of 6 units of heparin per mL of blood, are ideal for monitoring patients receiving moderate to high heparin dosages. For maximum heparin specificity, MAXACT contains multiple particulate activators - kaolin, celite, and glass beads - that ensure maximal Factor XII activation and compensate for potential patient sensitivity to a single activator.
 
Celite Tubes

Cat. No. Item
C-ACT Celite ACT Tubes (Black Flip-Top),
50 tubes/box

C-ACT Tubes contain a celite (diatomaceous earth) activator and can be used to monitor patients undergoing procedures requiring administration of moderate to high heparin concentrations.
 
Kaolin ACT Tubes

Cat. No. Item
K-ACT Kaolin ACT Tubes (Yellow Flip-Top), 50 tubes/box

Kaolin ACT Tubes are useful in monitoring patients receiving moderate to high heparin concentrations in the presence of aprotinin.
 
Glass Bead ACT Tubes

Cat. No. Item
G-ACT Glass Bead ACT Tubes (White Flip-Top),
50 tubes/box

The Glass Bead ACT is useful for monitoring patients undergoing procedures requiring low to moderate heparin dosages.
 
 
- Actalyke Quality Control -

Whole Blood Control Kit for MAX-ACT,
C-ACT, K-ACT


Cat. No. Item
AQC-H Whole Blood QC Kit

1 x 3 mL QC Level - I   1 x 3 mL QC Level - III
1 x 7 mL Distilled H20   1 x 7 mL CaCl2 (0.02 M)

The kit provides two levels of quality control, normal and
high. The lyophilized control is stable 4 hours at room
temperature once reconstituted.
 
Whole Blood Control Kit for G-ACT

Cat. No. Item
AQC-L G-ACT Whole Blood QC Kit

1 x 3 mL QC Level - I   1 x 3 mL QC Level - II
1 x 7 mL Distilled H20   1 x 7 mL CaCl2 (0.02 M)

The kit provides two levels of quality control, normal and low. The lyophilized control is stable 4 hours at room temperature once reconstituted.
 
Actalyke Electronic Clotting Tube

Cat. No. Item
XL-ECT Actalyke Electronic Clotting Tube

The Electronic Clotting Tube simulates patient sample clots at three therapeutic heparin levels: 100, 300 and 500 seconds
for daily QC of all Actalyke instruments.